Enable Intermediate FDRs
By default, PacketWise emits flow detail records at the end of a flow. To change this behavior so that PacketWise emits flow detail records at a set interval (optional), you need to enable the intermediate FDR feature.
To configure intermediate FDRs using the browser interface, do the following:
- Click the setup tab.
- From the Choose Setup Page list, choose system variables.
- In the Flow Detail Records (FDR) section, change the Intermediate FDR setting from off (default) to on.
- For the Intermediate FDR Timeout variable, specify the number of milliseconds between the emission of intermediate FDRs. The default is 15000 milliseconds.
- To commit the changed settings, scroll to the top of the page and click apply changes (a unit reset is not required).
See also:
Flow Detail Records Overview
Enable/Disable an FDR Collector
Remove an FDR Collector
FDR Troubleshooting
|